Caterpillar Model G3520C Natural Gas Generator Set, Rated at 2050 kW, Continuous each 4160 Volt, 2562 KVA, 4160 Volt, 3 Phase, 60 Hz, 1800 RPM
Description: Natural Gas Generator Set Make/Model: Caterpillar G3520C, serial GZA00306, arrangement 455-7241 Generator: SR4B, serial 8XS00590, Frame 828, 2 bearings Year: 2015 Rating: 2050 Electric kW @ 1800 RPM, continuous duty Voltage: 4160 V Hour Meter: 42,758 Hours Equipped with: • EMCP4.3 Control panel • Caterpillar digital voltage regulator • Woodward load sharing module • 24 VDC / 50A Wall-Mounted battery charger (600V) • Stand-alone 120V prelub pump • Stand-alone 600V/9kW block-heater w/ circulating pump • Ingersoll Rand pneumatic turning tool (engine mounted) • Generator space heater 120V • Kenco oil level controller • Murphy oil level Switch gauge • Solberg crankcase ventilation system Currently in good condition. A top end overhaul was performed at 33,000 hours. The regular maintenance was always performed as per attached calendar. Always ran with Caterpillar NGEO Advanced 40 oil and Caterpillar NGEC coolant, both on sampling analysis program.
Description: Natural Gas Generator Set Make/Model: Caterpillar G3520C, serial GZA00307, arrangement 455-7241 Generator: SR4B, serial 8XS00591, Frame 828, 2 bearings Year: 2015 Rating: 2050 Electric kW @ 1800 RPM, continuous duty Voltage: 4160 V Hour Meter: 48,078 Hours Equipped with: • EMCP4.3 Control panel • Caterpillar digital voltage regulator • Woodward load sharing module • 24 VDC / 50A Wall-Mounted battery charger (600V) • Stand-alone 120V prelub pump • Stand-alone 600V/9kW block-heater w/ circulating pump • Ingersoll Rand pneumatic turning tool (engine mounted) • Generator space heater 120V • Kenco oil level controller • Murphy oil level Switch gauge • Solberg crankcase ventilation system Currently in good condition. A top end overhaul was performed at 32,000 hours. The regular maintenance was always performed as per attached calendar. Always ran with Caterpillar NGEO Advanced 40 oil and Caterpillar NGEC coolant, both on sampling analysis program.
Description: Natural Gas Generator Set Make/Model: Caterpillar G3520C, serial GZA00308, arrangement 455-7241 Generator: SR4B, serial 8XS00592, Frame 828, 2 bearings Year: 2015 Rating: 2050 Electric kW @ 1800 RPM, continuous duty Voltage: 4160 V Hour Meter: 47,962 Hours Equipped with: • EMCP4.3 Control panel • Caterpillar digital voltage regulator • Woodward load sharing module • 24 VDC / 50A Wall-Mounted battery charger (600V) • Stand-alone 120V prelub pump • Stand-alone 600V/9kW block-heater w/ circulating pump • Ingersoll Rand pneumatic turning tool (engine mounted) • Generator space heater 120V • Kenco oil level controller • Murphy oil level Switch gauge • Solberg crankcase ventilation system Currently out of service, needs repairs. There is a crack on the engine block, located at the inspection door #12. The connecting rod cap came loose after a bolt breakage and made contact with the block. Repairable with cold stitching. A top end overhaul was performed at 47,000 hours. The regular maintenance was always performed as per attached calendar. Always ran with Caterpillar NGEO Advanced 40 oil and Caterpillar NGEC coolant, both on sampling analysis program.
Description: Natural Gas Generator Set Make/Model: Caterpillar G3520C, serial GZA00309, arrangement 455-7241 Generator: SR4B, serial 8XS00593, Frame 828, 2 bearings Year: 2015 Rating: 2050 Electric kW @ 1800 RPM, continuous duty Voltage: 4160 V Hour Meter: 42,450 Hours Equipped with: • EMCP4.3 Control panel • Caterpillar digital voltage regulator • Woodward load sharing module • 24 VDC / 50A Wall-Mounted battery charger (600V) • Stand-alone 120V prelub pump • Stand-alone 600V/9kW block-heater w/ circulating pump • Ingersoll Rand pneumatic turning tool (engine mounted) • Generator space heater 120V • Kenco oil level controller • Murphy oil level Switch gauge • Solberg crankcase ventilation system Currently in good condition. A top end overhaul was performed at 17,000 hours. Valve recession monitored. Pistons’ top and cylinders heads cleaning due at 44,000 hours. The regular maintenance was always performed as per attached calendar. Always ran with Caterpillar NGEO Advanced 40 oil and Caterpillar NGEC coolant, both on sampling analysis program.
Description: Natural Gas Generator Set Make/Model: Caterpillar G3520C, serial GZA00310, arrangement 455-7241 Generator: SR4B, serial 8XS00594, Frame 828, 2 bearings Year: 2015 Rating: 2050 Electric kW @ 1800 RPM, continuous duty Voltage: 4160 V Hour Meter: 45,204 Hours Equipped with: • EMCP4.3 Control panel • Caterpillar digital voltage regulator • Woodward load sharing module • 24 VDC / 50A Wall-Mounted battery charger (600V) • Stand-alone 120V prelub pump • Stand-alone 600V/9kW block-heater w/ circulating pump • Ingersoll Rand pneumatic turning tool (engine mounted) • Generator space heater 120V • Kenco oil level controller • Murphy oil level Switch gauge • Solberg crankcase ventilation system Currently in good condition. A top end overhaul was performed at 18,000 hours. Valve recession monitored. Pistons’ top and cylinders heads cleaning due at 46,000 hours. The regular maintenance was always performed as per attached calendar. Always ran with Caterpillar NGEO Advanced 40 oil and Caterpillar NGEC coolant, both on sampling analysis program.
Description: Natural Gas Generator Set Make/Model: Caterpillar G3520C, serial GZA00311, arrangement 455-7241 Generator: SR4B, serial 8XS00595, Frame 828, 2 bearings Year: 2015 Rating: 2050 Electric kW @ 1800 RPM, continuous duty Voltage: 4160 V Hour Meter: 51,321 Hours Equipped with: • EMCP4.3 Control panel • Caterpillar digital voltage regulator • Woodward load sharing module • 24 VDC / 50A Wall-Mounted battery charger (600V) • Stand-alone 120V prelub pump • Stand-alone 600V/9kW block-heater w/ circulating pump • Ingersoll Rand pneumatic turning tool (engine mounted) • Generator space heater 120V • Kenco oil level controller • Murphy oil level Switch gauge • Solberg crankcase ventilation system Currently in good condition. A top end overhaul was performed at 25,000 hours. Valve recession monitored. Pistons’ top and cylinders heads cleaning currently due. The regular maintenance was always performed as per attached calendar. Always ran with Caterpillar NGEO Advanced 40 oil and Caterpillar NGEC coolant, both on sampling analysis program.
Description: Natural Gas Generator Set Make/Model: Caterpillar G3520C, serial GZA00312, arrangement 455-7241 Generator: SR4B, serial 8XS00596, Frame 828, 2 bearings Year: 2015 Rating: 2050 Electric kW @ 1800 RPM, continuous duty Voltage: 4160 V Hour Meter: 53,431 Hours Equipped with: • EMCP4.3 Control panel • Caterpillar digital voltage regulator • Woodward load sharing module • 24 VDC / 50A Wall-Mounted battery charger (600V) • Stand-alone 120V prelub pump • Stand-alone 600V/9kW block-heater w/ circulating pump • Ingersoll Rand pneumatic turning tool (engine mounted) • Generator space heater 120V • Kenco oil level controller • Murphy oil level Switch gauge • Solberg crankcase ventilation system Currently in good condition. A top end overhaul was performed at 27,000 hours. Valve recession monitored. Pistons’ top and cylinders heads cleaning currently due. Complete engine dismantling recommended for wear conditions assessment, and to set the major overhaul calendar for the fleet. The regular maintenance was always performed as per attached calendar. Always ran with Caterpillar NGEO Advanced 40 oil and Caterpillar NGEC coolant, both on sampling analysis program.
Description: Natural Gas Generator Set Make/Model: Caterpillar G3520C, serial GZA00320, arrangement 455-7241 Generator: SR4B, serial 8XS00597, Frame 828, 2 bearings Year: 2017 Rating: 2050 Electric kW @ 1800 RPM, continuous duty Voltage: 4160 V Hour Meter: 42,411 Hours Equipped with: • EMCP4.3 Control panel • Caterpillar digital voltage regulator • Woodward load sharing module • 24 VDC / 50A Wall-Mounted battery charger (600V) • Stand-alone 120V prelub pump • Stand-alone 600V/9kW block-heater w/ circulating pump • Ingersoll Rand pneumatic turning tool (engine mounted) • Generator space heater 120V • Kenco oil level controller • Murphy oil level Switch gauge • Solberg crankcase ventilation system Currently out of service, repairs needed. A top end overhaul was performed at 32,000 hours. Valve recession monitored. Pistons’ top and cylinders heads cleaning currently due. The fuel metering valve (Raptor Valve) has to be replaced. We have the valve, but it is a newer version, and it is not a direct replacement. All the gas piping and related fittings to be ordered. A dealer certified technician will be required to flash the ECM with the latest flash file. The regular maintenance was always performed as per attached calendar. Always ran with Caterpillar NGEO Advanced 40 oil and Caterpillar NGEC coolant, both on sampling analysis program.